Alarm 53 Carrier Transicold
By Ing. Gerson Mora – October 17, 2022

Alarm 53 on Carrier Transicold units is triggered when the container’s temperature is not within the normal range or fails to reach the desired value within a specified time. Below are some key troubleshooting steps to address this issue:

Possible Causes and Solutions:

  1. Leaking Doors:
    Inspect all doors to ensure they are completely sealed and closed properly.
  2. Defrost Cycle:
    Initiate a manual defrost cycle. Ensure the cycle completes automatically.
  3. Low Refrigerant Pressure:
    Check for Alarm 18, which may indicate low refrigerant levels.
  4. Evaporator Airflow:
    Verify the presence of Alarm 56, which could signal airflow issues in the evaporator.
  5. System Pressures:
    The low and high system pressures should be within the normal range and match the values displayed on the system panel.