Cooling Load Calculation for Air Conditioning

This tool will help you estimate the cooling capacity (in Watts, BTU/h, and Tons of Refrigeration) required for a space, considering its physical characteristics, environmental conditions, and internal heat sources. Follow the steps below to use it:

Accessing the Tool:

Go to the webpage where the application is hosted. You will see a form divided into several sections.

Step 1: Units

  • Temperature Unit: Select the temperature unit you prefer to use for indoor and outdoor temperatures. Move the toggle switch to “°C” for Celsius or “°F” for Fahrenheit.
  • Size Unit: Select the unit of measurement for room dimensions. Move the toggle switch to “Meters” for Meters or “Feet” for Feet.

Step 2: Room Conditions

  • Room Temperature: Enter the desired indoor temperature for the space (in the unit you selected in Step 1). This is your air conditioning system’s setpoint.
  • Room Humidity: Select the typical humidity level expected in the room based on its use. Different uses generate varying amounts of latent heat, which affects the total load.
    • Bedroom: Medium Humidity
    • Library: Low Humidity
    • Office: Medium Humidity
    • Hospital: High Humidity
    • Kitchen: Very High Humidity

Step 3: Air Conditioner Type

  • Cooling System: Choose the type of air conditioning system you plan to install, as this influences how ventilation is handled.
    • Ducted with Fresh Air: Ducted systems that introduce new outdoor air. These require higher capacity.
    • Split without Fresh Air: Split (or mini-split) systems that primarily recirculate indoor air without actively introducing outdoor air (ventilation is considered through natural infiltration).

Step 4: Room Size

Enter the dimensions of the room. Make sure to use the units you selected in Step 1.

  • Room Length: The length of the room.
  • Room Width: The width of the room.
  • Room Height: The height of the room.

As you enter the dimensions, you will see a simple floor plan drawn in the “Room Plan (Top View)” area. This helps visualize the space’s shape.

Step 5: Walls, Windows, and Ceiling

This section allows you to define the characteristics of the surfaces enclosing the space, as heat transfers through them. Walls are labeled A, B, C, D. The floor plan visualization shows you which wall corresponds to each letter (generally A and C are length, B and D are width, assuming a rectangular shape).

  • Wall Settings: For each wall (A, B, C, D):
    • Wall Material: Select the construction material of the wall from the list. Each material has a predefined U-value (heat transfer coefficient). A low U-value indicates better insulation.
    • Custom U-Value (If you select “Custom U-Value”): If you choose “Custom U-Value,” a field will be enabled for you to manually enter the wall’s U-value in W/m²·K. This is useful if you know the exact value for your construction.
    • Sun Exposure: Check this box if the wall receives direct sunlight during peak heat hours. Sun exposure increases the heat load.
    • Has Window: Check this box if the wall has a window. Checking it will enable the window configuration options.
  • Window Settings (only if “Has Window” is checked): For each window on the wall:
    • Window Size: Enter the total area of the window on that wall (in the size units you selected in Step 1, squared, e.g., m² or ft²). The tool might automatically cap the maximum window size at 80% of the wall area to prevent unrealistic values.
    • Window Type: Select the type of glass and treatment for the window. Each type has predefined SC (Solar Heat Gain Coefficient) factors and U-values that affect heat gain from solar radiation and conduction, respectively. A low SC and a low U are better for cooling.
    • Shading Type: Select the type of external shading present for that window. Shading significantly reduces solar heat gain. Shading factors reduce the impact of solar radiation.
  • Ceiling:
    • Ceiling Material: Similar to walls, select the ceiling material or choose “Custom U-Value” to enter a value manually in W/m²·K.
    • Sun Exposure: Check if the ceiling receives direct sunlight.

Step 6: Internal Loads

Enter the number of heat sources inside the room.

  • Number of People: Enter the average number of people who will occupy the space simultaneously. Each person emits heat (sensible and latent).
  • Lighting Settings:
    • Number of Lights: Enter the total number of light fixtures.
    • Lighting Type: Select the type of bulb/fixture. Different types generate varying amounts of heat per unit.
  • Equipment Settings: Enter the number of electronic devices or equipment that will be operating and generating heat.
    • High-Heat Devices: Equipment that generates significant heat (e.g., servers, ovens).
    • Medium-Heat Devices: Equipment that generates moderate heat (e.g., desktop computers, large TVs).
    • Low-Heat Devices: Equipment that generates little heat (e.g., laptops, small monitors).

Step 7: Ventilation and Infiltration

These factors consider the entry of outdoor air, which often needs to be cooled and dehumidified.

  • Ventilation Flow Type: Select the primary use of the space. This helps determine the amount of outdoor ventilation air required according to typical standards (ASHRAE 62.1).
  • Infiltration Level: Indicate how airtight the space is. Infiltration is uncontrolled outdoor air entering through cracks and openings.
    • Tight: Very well-sealed space, low infiltration.
    • Normal: Space with average sealing.
    • Leaky: Space with many air leaks.

Step 8: Outdoor Conditions

  • Outdoor Temperature: Enter the design outdoor temperature for the calculation (in the unit you selected in Step 1). This should be the highest temperature expected on the hottest days of the year.
  • Peak Solar Hour: Select the time of day when you expect the cooling load to be maximum. Solar gain varies throughout the day.

Step 9: Calculate

Once you have filled in all the fields, click the “Calculate Cooling Load” button.

Step 10: View Results

The page will update to show the calculation results. You will see:

  • Detailed Results: A table showing the heat load ( in Watts) contributed by each component (Walls, Ceiling, Windows, Internal, Ventilation, Infiltration).
  • Total Load: The total calculated cooling load in Watts, BTU/h, and Tons of Refrigeration.

Interpreting the Results:

The “Total Load” indicates the minimum recommended cooling capacity for your air conditioning system. It is important to select equipment with a capacity equal to or slightly greater than this calculated value. An undersized unit will not adequately cool the space, while an oversized one can lead to inefficient cooling and humidity problems.

The “Detailed Results” table shows you which components contribute most to the heat load, which can help identify areas where improvements could be made to reduce cooling needs (e.g., improving wall or ceiling insulation, using windows with better properties, or adding shading).

Important Notes:

  • This calculation is an estimate and is based on simplifications. A professional calculation by an HVAC engineer may be necessary for complex or critical projects.
  • The U-values, SC factors, and ventilation/infiltration rates used in the tool are typical values or based on general standards (like ASHRAE). Actual material properties and site conditions may vary.
  • Latent load (moisture removal) is also a significant part of the total heat load calculation, especially in humid climates. The tool considers latent load from people, ventilation, and infiltration.

We hope this tool is useful for estimating your cooling needs!