The following is a comprehensive list of ELECTROLUX air conditioner error codes, their meanings, and common issues:

Error CodeDescription
E1Malfunction of the room temperature sensor.
E2Anti-freezing protection.
E3System blockage or refrigerant leakage.
E4High-temperature protection at the compressor’s exhaust.
E5Overcurrent protection.
E6Communication error between indoor and outdoor units.
E8, H4High-temperature warning.
H6No feedback from the indoor unit’s fan motor.
LPCommunication error between outdoor and indoor units.
L3Malfunction of the outdoor fan motor.
L9Current protection activated.
F0Refrigerant condensation detected.
F1Room sensor open circuit or short circuit.
F2Piping temperature sensor open circuit or short circuit.
F3Outdoor temperature sensor open circuit or short circuit.
F4Outdoor piping temperature sensor open circuit or short circuit.
F5Discharge sensor open circuit or short circuit.
F6Overload/drop frequency limit detected.
F8Overcurrent/drop frequency limit detected.
F9High discharge temperature warning.
FHAnti-freezing protection limit.
H1Defrosting mode active.
H3Compressor overload protection.
H5IPM protection.
HCPFC protection.
EEEEPROM error.
PHHigh-voltage protection.
PLLow-voltage protection.
U7Anomaly in the four-way valve operation.
P0Compressor operating at low frequency (test mode).
P1Compressor operating at standard frequency (test mode).
P2Compressor operating at maximum frequency (test mode).
P3Compressor operating at intermediate frequency (test mode).
LUPower warning.
EUTemperature warning.

Additional Common Errors in ELECTROLUX Air Conditioners

1. Power Loss

  • Symptoms: No sound from the air conditioner when opening the fuse.
  • Root Cause: Loose circuit, defective fuse, or damaged control board.

2. Remote Control Malfunction

  • Symptoms: The remote control sends signals to the air conditioner, but the unit does not respond.
  • Root Cause: Faulty remote control, dead batteries, or damaged control board.

3. Unpleasant Odors from the Air Conditioner

  • Symptoms: The unit emits an unpleasant smell.
  • Root Cause: Gas odor from refrigerant leakage or mold odor due to prolonged lack of cleaning and maintenance.

4. Unit Malfunction

  • Symptoms: Water leakage, condensation on the casing, misty air output, or frost accumulation.
  • Root Cause: Clogged drainage pipes, slow or non-functional fan, or frost buildup.

5. Lack of Cooling

  • Symptoms: Warm and stale air output.
  • Root Cause: Low refrigerant levels, faulty outdoor fan, or a malfunctioning indoor control board.

Expanded Error Code Table

Error CodeMeaning
E2Anti-freezing protection.
E3System blockage or refrigerant leakage.
E4High-temperature protection at the compressor’s exhaust.
E5Overcurrent protection.
E6Communication failure between indoor and outdoor units.
E8High-temperature protection.
H4High-temperature protection.
H6No feedback from the indoor fan motor.
C5Bridge malfunction protection.
LPIndoor and outdoor units mismatch.
L3Outdoor DC fan malfunction.
L9Power protection.
F0Refrigerant collection issue.
F1Indoor ambient sensor open circuit/short circuit.
F2Indoor piping sensor open circuit/short circuit.
F3Outdoor ambient sensor open circuit/short circuit.
F4Outdoor piping sensor open circuit/short circuit.
F5Discharge sensor open circuit/short circuit.
F6Overload frequency limit.
F8Overcurrent frequency limit.
F9High discharge temperature frequency limit.
FHAnti-freezing frequency limit.
H1Defrost mode active.
H3Compressor overload protection.
H5IPM protection.
HCPFC protection.
EEEEPROM malfunction.
PHHigh-voltage protection.
PLLow-voltage protection.
U7Abnormal four-way valve operation.
P0-P3Compressor frequency limits in various test modes.
LU/EUFrequency limitations for power or module temperature.

Leave a Reply