Skip to content
Home » Error Codes for DAWLANCE Air Conditioners

Error Codes for DAWLANCE Air Conditioners

How Many Temperature Sensors Can an Air Conditioner Have?

DAWLANCE air conditioners may include several temperature sensors, each with a specific purpose. Let’s explore the common types and their associated error codes.


Common Types of Sensors in DAWLANCE Air Conditioners

  1. Ambient Temperature Sensor
    • Measures the air temperature in the surrounding environment.
    • A malfunction triggers the E1 error code.
  2. Well Sensor
    • Monitors the evaporator’s temperature to detect potential freezing issues.
    • A fault generates the E2 error code.

Additional Sensors in Inverter Units

With the advent of inverter air conditioners, additional sensors have been introduced to enhance system performance:

  1. Condenser Sensor
    • Measures the refrigerant temperature inside the outdoor coil.
    • A failure in this sensor results in the E3 error code.
  2. Outdoor Ambient Sensor
    • Monitors the temperature of the air drawn by the outdoor unit’s fan.
    • A malfunction displays the E4 error code.

Diagnosing Temperature Sensor Failures

If you suspect an issue with the sensors, follow these steps to identify and resolve the problem:

1. Restart the System

  • Turn off the air conditioner and unplug it for several minutes.
  • Power it back on and check if the error persists.

2. Inspect the Connections

  • Clean and check the sensor connections to ensure they are secure.
  • Confirm the sensor is properly positioned.

3. Measure the Sensor’s Resistance

  • Disconnect the sensor from the electronic board.
  • Use a multimeter to measure its resistance.
  • Compare the results with the manufacturer’s specifications.
  • If reference values are unavailable, gently warm the sensor with your fingers: its resistance should decrease as the temperature increases.

4. Check the Sensor’s Power Supply

  • With the sensor connected, use a multimeter set to DC voltage to measure the supplied voltage.
  • A reading close to 2.5 V indicates proper operation.

5. Inspect the Electronic Board

  • If the sensor and its connections are in good condition but the error persists, the electronic board might not be supplying the correct voltage.

The Importance of Sensors

Temperature sensors play a crucial role in:

  • Detecting issues like freezing, overheating, or extreme temperature fluctuations.
  • Optimizing energy efficiency by managing the thermodynamic states of the refrigerant.

Leave a Reply