Error Codes for MUNDOCLIMA Air Conditioning Units

These error codes are categorized by the series of units.


Series: MUPR-H3 / MUPR-H4 / MUPR-H6

Error CodeDescriptionSolution
E0EEPROM error in the indoor unit.Check and replace the EEPROM if necessary.
E1Communication error between the outdoor and indoor units.Check the communication connections and wiring between the units.
E2Zero-cross detection error.Check the zero-cross circuit and replace defective components.
E3Open circuit or short circuit in the indoor unit’s ambient temperature sensor (T1).Check the T1 sensor and replace it if faulty.
E4Open circuit or short circuit in the outdoor unit’s pipe temperature sensor (T3).Check the T3 sensor and replace it if faulty.
E5Overcurrent protection.Check and fix electrical system overloads.
CERefrigerant leakage detected.Inspect the refrigerant system for leaks and repair them.
F0Overcurrent protection in the outdoor unit.Check the outdoor unit’s current and fix overloads.
F1Open circuit or short circuit in the outdoor unit’s ambient temperature sensor (T4).Check the T4 sensor and replace it if faulty.
F2Open circuit or short circuit in the outdoor unit’s pipe temperature sensor (T3).Check the T3 sensor and replace it if faulty.
F3IGBT overcurrent protection or IPM malfunction.Verify the IGBT/IPM module and replace it if necessary.
F4Voltage protection (high/low).Check the power supply and stabilize the voltage.
F5High temperature protection at the compressor head.Inspect the compressor, improve ventilation if necessary.
P0Overcurrent protection in the indoor unit.Inspect the electrical system and fix overloads.
P1High discharge temperature protection.Check the discharge temperature sensor and compressor operating conditions.
P2Refrigerant overload protection.Adjust the refrigerant charge to the correct level.
P4High temperature protection inside the battery.Improve ventilation and check operating conditions.

Series: MUPR-H5 / MUPR-H5A

Error CodeDescriptionSolution
E1Ambient temperature sensor error in the indoor unit.Check and replace the sensor.
E2Pipe temperature sensor error in the outdoor unit.Check and replace the sensor.
E3Pipe temperature sensor error in the indoor unit.Check and replace the sensor.
E4Indoor unit fan or PCB error.Inspect the fan and PCB, replace defective components.
E5/5ECommunication error between indoor and outdoor units.Check the communication connections and wiring between the units.
F0Outdoor unit fan or PCB error.Inspect the fan and PCB, replace defective components.
F1IPM (Inverter) module error in the outdoor unit.Check and replace the IPM module if necessary.
F2PFC module error in the outdoor unit.Check and replace the PFC module if necessary.
F3Compressor operation error.Verify the compressor and its operating conditions.
F4Discharge temperature sensor error in the outdoor unit.Check and replace the discharge sensor.
F5High temperature protection at the compressor head.Check the compressor operating conditions and improve ventilation.
F6Ambient temperature sensor error in the outdoor unit.Check and replace the ambient temperature sensor.
F7Voltage protection (high/low).Stabilize the power supply and check the operating voltage.
F8Communication error between PCBs in the outdoor unit.Check the communication connections and wiring between PCBs.
F9EEPROM error in the outdoor unit.Check and replace the EEPROM if necessary.
FASuction temperature sensor error in the outdoor unit.Check and replace the suction temperature sensor.
P4High temperature protection inside the battery.Improve ventilation and check operating conditions.

Series: MULTISPLIT-H6M

Error CodeDescriptionSolution
E0EEPROM error in the indoor unit.Check and replace the EEPROM if necessary.
E1Communication error between the outdoor and indoor units.Check the communication connections and wiring between the units.
E3Open circuit or short circuit in the indoor unit’s ambient temperature sensor (T1).Check the T1 sensor and replace it if faulty.
E4High condensate level protection (Cassette and Duct types only).Check and empty the condensate system.
E5Overcurrent protection.Inspect the electrical system and fix overloads.
EEOperating mode conflict.Adjust the operating mode according to specifications.
F0Overcurrent protection in the outdoor unit.Check the outdoor unit’s current and fix overloads.
F1Open circuit or short circuit in the outdoor unit’s ambient temperature sensor (T4).Check the T4 sensor and replace it if faulty.
F2Open circuit or short circuit in the outdoor unit’s pipe temperature sensor (T3).Check the T3 sensor and replace it if faulty.
F3IGBT overcurrent protection or IPM malfunction.Verify the IGBT/IPM module and replace it if necessary.
F4Voltage protection (high/low).Check the power supply and stabilize the voltage.
F5High temperature protection at the compressor head.Inspect the compressor, improve ventilation if necessary.
P0Overcurrent protection in the indoor unit.Inspect the electrical system and fix overloads.
P1High discharge temperature protection.Check the discharge temperature sensor and compressor operating conditions.
P3Low ambient temperature protection.Adjust operating conditions to maintain appropriate temperature levels.
P4Low-pressure protection in the compressor.Check the refrigerant level and adjust as needed.