The E9 error code in air conditioners can be confusing, as its meaning varies significantly depending on the brand and, in some cases, the specific model of the unit. In this article, we will thoroughly analyze the various interpretations of error E9 and how to resolve it, grouping brands according to the cause of the issue.


1. Fault in the Drainage System

The E9 error may be related to issues in the condensate water drainage system of the evaporator or components such as the water pump or overflow switch.

Affected brands and their interpretations:

  • AUX: Fault in the water pump.
  • Gree (cassette type), Lennox, Mitsubishi, Midea, Sharp, Hitachi: Overflow protection triggered by the condensate float switch or sensor.

Technical Cause:
The switch or float sensor activates when the water level in the condensate tray exceeds a critical point. This automatically shuts down the unit to prevent water damage. The location of the switch may vary depending on the unit’s orientation.


2. Lack of Refrigerant Gas

The E9 error can also indicate a lack of refrigerant gas, which affects the performance of the air conditioning system.

Related brands:

  • Panasonic
  • Sanyo
  • Actron (certain models).

3. Issues in Multi-Evaporator Systems

In systems with multiple evaporators, the E9 error may have specific meanings depending on the brand:

  • Toshiba: Two local controllers in a group are both configured as master units.
  • York: Malfunction in twin evaporator systems.

4. Communication Failures

The E9 error can arise due to communication problems between the indoor and outdoor units.

Affected brands:

  • Electrolux
  • Haier
  • BM

5. Faults in the Electronic Board

In some cases, the E9 error is linked to failures in the electronic board, specifically in the intelligent power module (IPM).

Related brands:

  • Prime
  • Benelux

General Recommendations to Solve the E9 Error

  1. Check the user manual: Each model may have a specific interpretation of the error code.
  2. Verify connections: Ensure that electrical and wiring connections are properly secured.
  3. Inspect the air filter: A clogged filter can reduce airflow and trigger errors.
  4. Clean the condensate tray: Dirt buildup can block the drainage system and activate the E9 error.
  5. Check the refrigerant level: A lack of refrigerant may require a technician’s intervention.
  6. Restart the unit: Disconnect it from the power supply for a few minutes to reset the system.
  7. Contact an authorized technician: If you are unable to resolve the issue on your own, it is best to call a professional for accurate diagnosis and repair.