General Electric air conditioner error codes are often accompanied by audible signals, such as beeping, to indicate specific problems. Understanding the meaning of these error codes is essential for troubleshooting. If the buttons on your GE air conditioner are unresponsive, professional assistance may be required.


GE Portable Air Conditioner Error Codes

Error CodeMeaningSolution
P1 or H8Water tank fullDrain the water tank according to the instructions in the user manual.
E1 or F1Ambient temperature error
E2 or F2Evaporator sensor error
E4Display panel communication error
F4Outdoor temperature sensor error
F0Refrigerant sensor error
E5Overcurrent protection error
H3Compressor overload protection error
E8Overload malfunction error

GE Window Air Conditioner LED Error Codes

LED Error CodeMeaningSolution
Flashing “88” on LED displayNormal during startup for 2 secondsNo action required.
Flashing Cool LED lightFrozen evaporator coilsTurn off the unit and allow it to defrost. Clean the evaporator coils.
Flashing Red LED lightDirty air filterClean the air filters.

GE Window Air Conditioner Error Codes

Error CodeMeaningSolution
E1Electronic control board malfunctionRestart the unit’s electronic control board.
E2Temperature sensor errorRestart the unit.
E4Drain tray fullEmpty the drain tray.
E8Overload malfunction errorUnplug the unit for 30 seconds to reset it.

GE Mini-Split Air Conditioner Error Codes

Error CodeMeaningSolution
PEMain compressor sensor malfunction
E0EEPROM parameter error
E1Communication error between indoor and outdoor units
E2Signal error
E3Indoor fan speed malfunction
E5Open or short circuit in outdoor temperature sensor
E6Open or short circuit in ambient temperature sensor
P0Inverter module protection
P1Overvoltage or undervoltage protection
P2Compressor temperature protection
P3Outdoor temperature too low
P4Compressor drive error (inverter only)

GE Dehumidifier Air Conditioner Error Codes

Error CodeMeaningSolution
E0For 70-pint models: Water not pumping while in pump mode; E0 and pump light will flash on display.
E1Electronic control board malfunctionInspect the electronic control board for damage. Replace defective components.
E4Water bucket full or float switch malfunctionEmpty the water bucket. Check for pinched or damaged wires between the control panel and the float switch.
88“88” displayed when power is connected, this is normal.No action required.