Error E4 is a code that varies depending on the brand and type of air conditioner. Below, we outline the most common causes of this error and potential solutions by brand:
Error E4 in Different Brands and Models
General Electric (GE)
- Portable Models:
- Cause: Display panel communication error.
- Solution:
- Turn off and restart the unit by unplugging it for 30 seconds before plugging it back in.
- Check the wiring between the display panel and the unit.
- If the issue persists, update the unit’s software or contact a technician.
- Window Models:
- Cause: Full drain pan.
- Solution:
- Turn off the unit.
- Locate the drain pan and empty the accumulated water.
- Check for possible obstructions in the drain line or the air coils.
Carrier
- Indoor Units:
- Cause: Open or short circuit in the ambient temperature sensor (T1).
- Outdoor Units:
- Cause: Open or short circuit in the temperature sensor.
General Solution for Carrier: Contact technical support for a sensor inspection.
Midea
- Outdoor Units:
- Cause: High-temperature protection or faulty temperature sensor.
- Portable Models:
- Cause: Display panel communication error.
Solution: Restart the unit by unplugging it. If the error persists, contact authorized technical support.
Samsung
- Cause: Forced defrost due to low refrigerant levels, a defective pump, or a damaged temperature sensor.
- Solution: Contact the nearest Samsung service center for a comprehensive inspection.
York
- Standard Models:
- Cause: Failure in the ambient temperature sensor.
- Central Models:
- Cause: Malfunction in the T2B temperature sensor of the discharge pipe.
Solution: Replace or repair the temperature sensor with the help of a technician.
Bosh, Westinghouse, and Other Brands
- Common Cause: Open or short circuit in the ambient temperature sensor (T1).
- Solution: Check the integrity of the sensor. If it is damaged, replace it.
Gree and Electrolux
- Cause: High-temperature protection in the compressor exhaust.
- Solution:
- Turn off the unit and let it cool down.
- If the error persists, request technical assistance.
Haier and Sharp
- Cause in Indoor Models: EEPROM issues or a full water tank (portable models).
- Solution: Empty the water tank and check the internal software status.
Fujitsu and Kelvinator
- Cause: Open indoor coil thermistor or high-temperature discharge protection.
- Solution: Request a thermistor replacement or adjust refrigerant pressure.
Daikin
- Cause: Low-pressure switch (LBS) activation, indicating insufficient system pressure.
- Solution: Recharge the refrigerant and inspect the system for leaks.