General Error Codes

Error CodeMeaning
00HNo anomalies detected
11HData line error between the indoor and outdoor units
12HPower error between the outdoor and indoor units
14HAmbient temperature sensor error
15HCompressor discharge temperature sensor error
16HCompressor load current is too low
19HInternal fan lock error
23HCooler temperature sensor error
25HElectronic ion circuit error
27HOutdoor temperature sensor error
28HHot platform temperature sensor error
30HCompressor outlet temperature sensor error
33HConnection error between internal and external blocks
38HInternal and external block synchronization error
58HPatrol circuit error
59HEco patrol circuit error
97HOutdoor unit fan error
98HIndoor unit temperature too high (heating mode)
99HCooling temperature too low (freezing)
11FCooling/heating mode switch error
90FBost boost circuit failure for compressor power block
91FCompressor load line error too low
93FCompressor rotation speed error
95FHot platform temperature too high
96FCompressor power transistor overheating (Ipm)
97FCompressor temperature too high
98FCompressor load too high
99FCompressor DC output too high
P05AC power supply issue

Inverter Cooling-Only Air Conditioner Error Codes

Error CodeMeaning
F11Four-way valve switching anomaly
F17Freezing anomaly in reserve indoor units
F90Power Factor Correction (PFC) circuit protection
F91Refrigeration cycle anomaly
F93Abnormal compressor revolution
F94Compressor discharge overpressure protection
F95High outdoor cooling load
F96Overheating protection for power transistor module
F97Compressor overheating protection
F98Total operating current protection
F99Detection of outdoor DC (Direct Current) spikes

Eco-Friendly Air Conditioner Error Codes (Using R410A Refrigerant)

Error CodeMeaning
E01Remote control reception error
E02Remote control transmission error
E03Indoor unit error receiving central remote signal
E04Indoor unit error receiving outdoor unit signal
E05Indoor unit error transmitting signal to outdoor unit
E06Outdoor unit failed to receive serial communication signal from indoor unit
E07Outdoor unit sending failure to indoor unit
E08Duplicate indoor unit address configuration error
E09More than one remote control set with incorrect main error
E12Automatic address configuration prohibited while in progress
E13Indoor unit error transmitting signal to remote control
E14Duplicate main unit in multi-operation simultaneous control (detected by outdoor unit)
E15Automatic address alarm (capacity too low)
E16Automatic address alarm (capacity too high)
E18Defective communication in group control wiring
E20No indoor units connected

Additional Errors

Error CodeMeaning
F04Compressor discharge temperature sensor (TD) issue
F06Input temperature sensor (C1) problem in heat exchanger
F07Intermediate temperature sensor (C2) issue in heat exchanger
F08Outdoor air temperature sensor (TO) issue
F12Suction temperature sensor (TS) issue at compressor input
F31Non-volatile memory (EEPROM) issue in the outdoor unit
H01Primary overcurrent detected
H02PAM problem
H03Primary current CT sensor failure
H05Compressor discharge temperature sensor (TD) disconnected
H31HIC problem
L04Duplicate addresses in outdoor units
L10Outdoor unit capacity not configured
L13Indoor unit type configuration error
L18Four-way valve operation failure
P03Compressor discharge temperature problem
P04High-pressure problem
P05AC power supply issue
P13Alarm for open valve
P14Sensor detection issue
P15Insufficient gas level detected
P16Compressor overcurrent problem
P22Outdoor unit fan motor issue
P29Compressor INV wiring missing or failure (including locking) due to DCCT malfunction