General Error Codes
Error Code | Meaning |
---|---|
00H | No anomalies detected |
11H | Data line error between the indoor and outdoor units |
12H | Power error between the outdoor and indoor units |
14H | Ambient temperature sensor error |
15H | Compressor discharge temperature sensor error |
16H | Compressor load current is too low |
19H | Internal fan lock error |
23H | Cooler temperature sensor error |
25H | Electronic ion circuit error |
27H | Outdoor temperature sensor error |
28H | Hot platform temperature sensor error |
30H | Compressor outlet temperature sensor error |
33H | Connection error between internal and external blocks |
38H | Internal and external block synchronization error |
58H | Patrol circuit error |
59H | Eco patrol circuit error |
97H | Outdoor unit fan error |
98H | Indoor unit temperature too high (heating mode) |
99H | Cooling temperature too low (freezing) |
11F | Cooling/heating mode switch error |
90F | Bost boost circuit failure for compressor power block |
91F | Compressor load line error too low |
93F | Compressor rotation speed error |
95F | Hot platform temperature too high |
96F | Compressor power transistor overheating (Ipm) |
97F | Compressor temperature too high |
98F | Compressor load too high |
99F | Compressor DC output too high |
P05 | AC power supply issue |
Inverter Cooling-Only Air Conditioner Error Codes
Error Code | Meaning |
---|---|
F11 | Four-way valve switching anomaly |
F17 | Freezing anomaly in reserve indoor units |
F90 | Power Factor Correction (PFC) circuit protection |
F91 | Refrigeration cycle anomaly |
F93 | Abnormal compressor revolution |
F94 | Compressor discharge overpressure protection |
F95 | High outdoor cooling load |
F96 | Overheating protection for power transistor module |
F97 | Compressor overheating protection |
F98 | Total operating current protection |
F99 | Detection of outdoor DC (Direct Current) spikes |
Eco-Friendly Air Conditioner Error Codes (Using R410A Refrigerant)
Error Code | Meaning |
---|---|
E01 | Remote control reception error |
E02 | Remote control transmission error |
E03 | Indoor unit error receiving central remote signal |
E04 | Indoor unit error receiving outdoor unit signal |
E05 | Indoor unit error transmitting signal to outdoor unit |
E06 | Outdoor unit failed to receive serial communication signal from indoor unit |
E07 | Outdoor unit sending failure to indoor unit |
E08 | Duplicate indoor unit address configuration error |
E09 | More than one remote control set with incorrect main error |
E12 | Automatic address configuration prohibited while in progress |
E13 | Indoor unit error transmitting signal to remote control |
E14 | Duplicate main unit in multi-operation simultaneous control (detected by outdoor unit) |
E15 | Automatic address alarm (capacity too low) |
E16 | Automatic address alarm (capacity too high) |
E18 | Defective communication in group control wiring |
E20 | No indoor units connected |
Additional Errors
Error Code | Meaning |
---|---|
F04 | Compressor discharge temperature sensor (TD) issue |
F06 | Input temperature sensor (C1) problem in heat exchanger |
F07 | Intermediate temperature sensor (C2) issue in heat exchanger |
F08 | Outdoor air temperature sensor (TO) issue |
F12 | Suction temperature sensor (TS) issue at compressor input |
F31 | Non-volatile memory (EEPROM) issue in the outdoor unit |
H01 | Primary overcurrent detected |
H02 | PAM problem |
H03 | Primary current CT sensor failure |
H05 | Compressor discharge temperature sensor (TD) disconnected |
H31 | HIC problem |
L04 | Duplicate addresses in outdoor units |
L10 | Outdoor unit capacity not configured |
L13 | Indoor unit type configuration error |
L18 | Four-way valve operation failure |
P03 | Compressor discharge temperature problem |
P04 | High-pressure problem |
P05 | AC power supply issue |
P13 | Alarm for open valve |
P14 | Sensor detection issue |
P15 | Insufficient gas level detected |
P16 | Compressor overcurrent problem |
P22 | Outdoor unit fan motor issue |
P29 | Compressor INV wiring missing or failure (including locking) due to DCCT malfunction |