When installing an air conditioner, avoiding these common mistakes can significantly improve the system’s efficiency and longevity. Below are some typical errors and practical solutions to prevent them.


Error 1: Incorrect Placement of the Indoor Evaporator Unit

Proper placement of the indoor unit is critical for optimal cooling performance and efficiency.

Recommendations:

  • A. In small rooms, preferably place the unit on the wider wall.
  • B. In slightly larger rooms, place the unit on the shorter wall.
  • C. For large spaces, it is advisable to use two units.
  • D. Keep the unit away from doors, windows, heat sources, and dust to prevent interference with its operation.
  • E. Install the unit as high as possible, ensuring a proper distance from the ceiling.
  • F. Avoid placing the unit on top of appliances, as this can affect its performance.
  • G. Ensure correct placement of drainage hoses for condensate water to prevent leaks.

Solution: Follow these recommendations carefully and avoid using drainage pumps unless absolutely necessary.


Error 2: Incorrect Placement of the Outdoor Condenser Unit

The outdoor unit requires proper ventilation to ensure effective heat dissipation.

Problem: Insufficient ventilation can reduce the unit’s efficiency and increase energy consumption.

Solution:

  • A. Place the condenser unit in the coolest location available.
  • B. Do not obstruct the air outlets and maintain sufficient clearance from walls.
  • C. Ensure that the airflow to and from the unit is not blocked.

Error 3: Incorrect Pipe Insulation

Problem: Lack of independent insulation for each pipe can result in heat exchange, reducing system efficiency.

Solution: Each pipe should have its own insulation to prevent heat transfer and maintain optimal performance.


Error 4: Incomplete System Vacuum

Problem: Moisture or air remaining in the system can affect cooling performance and cause long-term damage.

Solution:

  • A. The installer must use a vacuum pump to remove all air and moisture from the system before releasing the refrigerant.
  • B. Performing a vacuum test can also help detect potential leaks before refrigerant is released.

Error 5: Incorrect Refrigerant Adjustment

Problem: Failing to adjust the refrigerant charge when modifying pipe lengths can lead to improper system operation.

Solution:

  • A. Always follow the manufacturer’s guidelines and monitor pressure values using gauges.
  • B. For reference, the standard operating pressure for R-410A is 121 psi, and for R-32, it is 129 psi.

Tips to Optimize Piping in a Split-Type Air Conditioner

Here are 10 essential tips to guarantee a smooth and efficient piping installation for split-type air conditioning systems:


1. Use a Tube Bender

  • Utilize a tube bender to prevent improper bends in the refrigerant lines.
  • Ensure that bends have a wide radius to maintain proper flow and reduce pressure drops.
  • Avoid sharp bends, as they can cause significant efficiency losses.

2. Minimize Pipe Bends

  • Reduce the number of bends in the piping to decrease friction losses and improve refrigerant flow.
  • Each additional bend increases the equivalent pipe length, which can affect system performance.
  • Wherever possible, install piping in a direct path between the indoor and outdoor units.

3. Follow the Recommended Maximum Length

  • Adhere to the maximum pipe length specified by the manufacturer according to the system’s capacity.
  • Exceeding this length can reduce performance and lead to operational issues.

4. Adjust Refrigerant Charge for Longer Pipes

  • If the pipes need to be extended, ensure the refrigerant charge is adjusted to account for the additional volume.
  • Refer to an appropriate chart to determine the exact amount of refrigerant to add.

5. Ensure Smooth Directional Changes

  • For transitions from vertical to horizontal piping, implement smooth directional changes with proper inclination.
  • This facilitates the return of oil accompanying the refrigerant from the compressor discharge.

6. Install Oil Traps in Vertical Risers

  • For systems with significant vertical pipe lengths, add oil traps to prevent oil accumulation in undesirable areas.
  • Proper oil circulation protects the compressor from damage caused by insufficient lubrication.

7. Optimize Unit Placement

  • Position the indoor and outdoor units as close as possible to minimize pipe separation.
  • Shorter distances improve heat exchange, reduce pressure losses, and enhance system efficiency.

8. Provide Proper Pipe Support

  • Install sturdy supports at regular intervals to prevent pipes from sagging or vibrating.
  • Proper support protects the lines from potential damage or leaks, maintaining the system’s integrity.

9. Maintain Original Pipe Diameters

  • Retain the original pipe diameters specified for the system and eliminate any unnecessary excess length.
  • This reduces pressure drops and improves overall system performance.

10. Ensure Proper Insulation

  • Insulate each pipe correctly and separately to prevent condensation and maintain thermal efficiency.
  • Proper insulation minimizes energy losses and prevents unwanted moisture formation.