YORK Air Conditioner Error Codes allow technicians or users to identify the cause of a malfunction or issue with the HVAC system.

Codes and Solutions:

CODE: E0
RESULT AND SOLUTION: Error in the indoor EEPROM (Electrically Erasable Programmable Read-Only Memory).

CODE: E1
RESULT AND SOLUTION: Communication malfunction between indoor and outdoor units.

CODE: E3
RESULT AND SOLUTION: Malfunction in the indoor fan speed.

CODE: E4
RESULT AND SOLUTION: Error in the indoor ambient temperature sensor.

CODE: E5
RESULT AND SOLUTION: Error in the evaporator coil temperature sensor.

CODE: EC
RESULT AND SOLUTION: Malfunction in the refrigerant leak detection system.

CODE: EE
RESULT AND SOLUTION: Malfunction in the water level alarm.

CODE: E8
RESULT AND SOLUTION: Communication malfunction in a dual indoor unit (dual model only).

CODE: E9
RESULT AND SOLUTION: Another twin model malfunctions.

CODE: F0
RESULT AND SOLUTION: Overload protection.

CODE: F1
RESULT AND SOLUTION: Error in the outdoor temperature sensor.

CODE: F2
RESULT AND SOLUTION: Error in the outdoor condenser tube sensor.

CODE: F3
RESULT AND SOLUTION: Error in the air discharge temperature sensor.

CODE: F4
RESULT AND SOLUTION: Error in the outdoor EEPROM.

CODE: F5
RESULT AND SOLUTION: Malfunction in the outdoor fan speed (DC fan motor only).

CODE: F6
RESULT AND SOLUTION: Error in the T2b sensor.

CODE: F7
RESULT AND SOLUTION: Communication error in the automatic lift panel.

CODE: F8
RESULT AND SOLUTION: Malfunction in the automatic lift panel.

CODE: F9
RESULT AND SOLUTION: Automatic lift panel is open.

CODE: P0
RESULT AND SOLUTION: Inverter module IPM protection.

CODE: P1
RESULT AND SOLUTION: High/low voltage protection.

CODE: P2
RESULT AND SOLUTION: Compressor top overheat protection.

CODE: P3
RESULT AND SOLUTION: Outdoor low-temperature protection.

CODE: P4
RESULT AND SOLUTION: Compressor drive error.

CODE: P5
RESULT AND SOLUTION: Mode conflict.

CODE: P6
RESULT AND SOLUTION: Compressor low-pressure protection.

CODE: P7
RESULT AND SOLUTION: Outdoor IGBT sensor error.


Central Controller Fault Codes for YORK:

CODE: H3
RESULT: Malfunction in the outdoor addition (valid for the main unit).

CODE: H2
RESULT: Malfunction in the outdoor reduction (valid for the main unit).

CODE: H1
RESULT: Network communication malfunction.

CODE: EF
RESULT: Another malfunction.

CODE: E4, T4
RESULT: Temperature sensor malfunction.

CODE: E3, T3
RESULT: Temperature sensor malfunction.

CODE: E2
RESULT: Sensor malfunction.

CODE: E1, E0
RESULT: Communication malfunction, phase sequence, or missing phase.

CODE: PF
RESULT: Other protection.

CODE: PE
RESULT: Oil balance.

CODE: PD
RESULT: Oil return.

CODE: PA
RESULT: Defrost protection.

CODE: P8
RESULT: Third compressor current protection.

CODE: P7
RESULT: Second compressor current protection.

CODE: P5
RESULT: High condenser temperature protection.

CODE: P4
RESULT: Discharge pipe temperature protection.

CODE: P3
RESULT: First compressor current protection.

CODE: P2
RESULT: Discharge low-pressure protection.

CODE: P1, P0
RESULT: High-pressure discharge protection. Compressor high-temperature protection.


YORK Outdoor Unit Error Codes:

CODE: E1
RESULT: Phase sequence error.

CODE: E2
RESULT: Communication malfunction between indoor and outdoor units.

CODE: E3
RESULT: T3 temperature sensor malfunction.

CODE: E4
RESULT: T4 temperature sensor malfunction.

CODE: E5
RESULT: T5 temperature sensor malfunction.

CODE: E6
RESULT: Water level alarm malfunction.


YORK Central Air Conditioning Error Codes:

CODE: EF
RESULT: Another malfunction. PF: Other protection.

CODE: EE
RESULT: Malfunction in water level verification. PE: Reserve.

CODE: ED
RESULT: Outdoor protection. PD: Reserve.

CODE: CE
RESULT: Clear reserve PC with malfunction.

CODE: EB
RESULT: Protection reserve PB for the inverter module.

CODE: EA
RESULT: Reserve PA overcurrent in the compressor (4 times).

CODE: E9
RESULT: Communication malfunction between the PCB and the display board reserve P9.

CODE: E8
RESULT: Fan motor out of control. P8: Compressor overcurrent.

CODE: E7
RESULT: EEPROM malfunction. P7: Overvoltage/low power protection.

CODE: E6
RESULT: Zero-crossing verification malfunction. P6: Discharge low-pressure protection.

CODE: E5
RESULT: T3 sensor malfunction. High-pressure discharge protection P5.

CODE: E4
RESULT: T2B sensor malfunction. Discharge pipe temperature protection P4.

CODE: E3
RESULT: T2A sensor malfunction. Compressor temperature protection P3.

CODE: E2
RESULT: T1 sensor malfunction. High condenser temperature protection P2.

CODE: E1
RESULT: Communication malfunction. P1: Anti-freezing or defrost protection.

CODE: E0
RESULT: Phase sequence or missing phase. P0: Evaporator temperature protection.

CODE: 03#
RESULT: Communication malfunction between CCM/PC (gateway).

CODE: 02#
RESULT: Communication malfunction in the function module/CCM.

CODE: 01#
RESULT: Communication malfunction between CCM/NIM.

CODE: 00#
RESULT: Communication malfunction between CCM/PCB.


YORK Wall-Mounted Air Conditioner Error Codes:

CODE: E7
RESULT: Communication failure between indoor and outdoor units.

CODE: E1
RESULT: Ambient temperature sensor failure.

CODE: E4
RESULT: Indoor EEPROM error.

CODE: E14
RESULT: Indoor fan motor malfunction.

CODE: F12
RESULT: Outdoor EEPROM error.

CODE: F1
RESULT: IPM protection.

CODE: F22
RESULT: Overcurrent protection for outdoor AC electricity models